FDA RECALL RECORD · Z-0238-2026

BD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927. Recall

BD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.

FDA recall Class II

Ongoing

FDA lists this Class II recall for BD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.. Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-0238-2026
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
Sep 23, 2025
FDA report date
Oct 29, 2025
Quantity in commerce
62 units
Distribution
See key details
FDA cause
Software design

What is being recalled?

BD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.

Affected model & UDI checker

Search the exact identifiers published for Z-0238-2026.

The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.

Affected products

Model / catalog numberProductLot scope reportedUDI / GTIN
44191609BD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.Check source noticeNot specified
441927BD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.Check source noticeNot specified
Not specifiedBD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.Check source notice00382904419165
Not specifiedBD MAX System, for in vitro diagnostic (IVD) use, labeled as the following: 1. BD MAX System, BD MAX Instrument, Catalog Numbers: 44191609, 441927.Check source notice00382904419271
FDA code information

Catalog Number (Serial Numbers): 44191609, UDI/DI: 00382904419165, (CT0883, CT0636, CT0462, CT0303, CT1217, CT0257, CT0709, CT0786, CT0713, CT0765, CT0668, CT0930, CT0181, CT0564, CM0113, CM0126, CT1319, CT0634, CT1176, CT0910, CM0066, CT0540, CT0138, CM0072, CM0087, CT0534, CT0278, CM0047, CT2365, CT0242, CM0042, CT0558, CT0648, CT0723, CT0855, CT1179, CT0446, CM0125, CT0873, CT0875, CT1369, CM0009, CT0336, CT0879, CT1354, CT0309, CT0739, CT1767, CT1551, CT1320, CT1351), 441927, UDI/DI: 00382904419271, (CR1423A, CR0005, CR0009, CR0003, CT0592, CR0008, CR0941, CR0007, CM0105, CR0705, CR0589).

View the original FDA recall notice

Why was this product recalled?

Product service credentials used by some BD technical support teams to access certain BD products were accessed by an unauthorized actor. Until these product service credentials are updated, there is a risk of unauthorized access that may impact the confidentiality, integrity and/or availability of the relevant products and associated data.

What actions did Becton Dickinson & Co. take?

Beckton, Dickenson and Company notified consignees on about 09/23/2025 via mailed letter and email. This updated letter serves as a supplement to the original field action communication, dated 10/31/2024. It is intended to clarify that the previously described issue remains unchanged; however, the scope of the impacted product SKUs has been expanded. The update specifically documents additional SKUs including refurbished product codes that were not included in the original communication. Consignees were instructed to follow outlined best practices for maintaining strong security measures to protect hospital networks and medical devices, read and understand the recall notification, provide the letter to all applicable personnel or customers if further distributed, and complete and return the Customer Response Form.

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.

Our data sources and methodology