BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000; Recall
BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000;
FDA recall Class II
Ongoing
FDA lists this Class II recall for BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000;. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-0479-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Feb 2, 2023
- FDA report date
- Nov 19, 2025
- Quantity in commerce
- 167 units
- Distribution
- See key details
- FDA cause
- Under Investigation by firm
What is being recalled?
BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000;
Affected model & UDI checker
Search the exact identifiers published for Z-0479-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 1000 | BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000; | Check source notice | Not specified |
| Not specified | BEAR Implant (Bridge-Enhanced ACL Restoration); Model/Catalog: 1000; | Check source notice | 00860002987804 |
FDA code information
Model/Catalog: 1000; UDI-DI: 00860002987804; Lot number: 7008409;
Why was this product recalled?
The field action was initiated in February of 2023 and was limited to the affected lot from sales force trunk stock only.
What actions did Miach Orthopaedics take?
On January 30, 2023 RE: BEAR Implant Hydration memo emails were sent to sales staff. If you observe an implant that hydrates too quickly (e.g., less than 30 seconds) and appears that it may not remain intact upon insertion into the knee, do not attempt to implant the device. We would recommend you always have a backup device available to address such circumstances. We plan to revise the Tips and Pearls document, ML-1027, to provide further instructions/details on how to properly hydrate the BEAR device. In the meantime, one way to avoid shortened hydration time is to consider hydrating the dense side of the implant first and continue toward the porous side . To date, all reports of this observation have involved Lot # 7008409. As a precaution and to ensure customer satisfaction, we are asking that you return all devices from this lot that are currently in your trunk stock (in your possession). Chris Brown will work with you to coordinate returns as well as replacing these trunk stock devices. Please contact me ([email protected]) or Arjun ([email protected]) if you have questions.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-0479-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology