Brand Name: MST Duet Reusable Handle for Single Use Heads Product Name: Reusable Handle for Single Use Heads (Forceps and Scissors) Recall

Brand Name: MST Duet Reusable Handle for Single Use Heads Product Name: Reusable Handle for Single Use Heads (Forceps and Scissors) Model/Catalog Number: DFH-1028 Software Version: N/A Product Description: A MST Single Use Forceps or Scissors System consists of a reusable handle and one of a number of single use interchangeable heads. MST Single Use Forceps and Scissor heads are shipped ready to use sterile in a tray with Tyvek lid within a sterile pouch. MST Duet Reusable Handle for Single Use Forceps & Scissor Heads are supplied in a non-sterile condition and must be sterilized prior to and after every use. The blue sleeve the handle is packaged in is not intended to be sterilized and does not maintain sterility. Component: Yes. The MST Duet¿ Reusable Handle for Single Use Heads is the reusable handle component which connect to either Single Use Forceps or Scissors heads.

FDA recall Class II

Ongoing

FDA lists this Class II recall for Brand Name: MST Duet Reusable Handle for Single Use Heads Product Name: Reusable Handle for Single Use Heads (Forceps and Scissors). Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-0521-2025
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
Sep 17, 2024
FDA report date
Dec 4, 2024
Quantity in commerce
24
Distribution
See key details
FDA cause
Process control

What is being recalled?

Brand Name: MST Duet Reusable Handle for Single Use Heads Product Name: Reusable Handle for Single Use Heads (Forceps and Scissors) Model/Catalog Number: DFH-1028 Software Version: N/A Product Description: A MST Single Use Forceps or Scissors System consists of a reusable handle and one of a number of single use interchangeable heads. MST Single Use Forceps and Scissor heads are shipped ready to use sterile in a tray with Tyvek lid within a sterile pouch. MST Duet Reusable Handle for Single Use Forceps & Scissor Heads are supplied in a non-sterile condition and must be sterilized prior to and after every use. The blue sleeve the handle is packaged in is not intended to be sterilized and does not maintain sterility. Component: Yes. The MST Duet Reusable Handle for Single Use Heads is the reusable handle component which connect to either Single Use Forceps or Scissors heads.

Affected model & UDI checker

Search the exact identifiers published for Z-0521-2025.

The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.

Affected products

Model / catalog numberProductLot scope reportedUDI / GTIN
DFH-1028Brand Name: MST Duet Reusable Handle for Single Use Heads Product Name: Reusable Handle for Single Use Heads (Forceps and Scissors)Check source noticeNot specified
Not specifiedBrand Name: MST Duet Reusable Handle for Single Use Heads Product Name: Reusable Handle for Single Use Heads (Forceps and Scissors)Check source notice00844685005536
FDA code information

Lot Code: Product Codes: HNF or HNR (Regulation Number 886.4350). Either code can apply as the Duet Handle Assembly can be used with MST Duet Ophthalmic Scissors or MST Duet Forceps. UDI: 00844685005536 Lot #: 160458. Lot number is a sequential number generated through the internal SAP. All finished goods can be effectively traced by the lot number as either the finished good part or the sub part used. Expected life: The number of handle reprocessing cycles is not limited as long as the post-cleaning and pre-use inspections determine that the product is still functional and shows no signs of damage or corrosion.

View the original FDA recall notice

Why was this product recalled?

Due to pin coming off of handles.

What actions did MicroSurgical Technology Inc take?

On 09/24/2024, the firm sent via express mail a customer letter informing customers that there is a potential issue pertaining to the pins on the handle of the DFH-1028, Handle Assembly Lot Number 160458. The locking pins that actuate the head may be defective and could potentially dislodge without warning. As a precautionary measure, the firm is replacing the handle associated with the affected lot number 160458 at no cost to customers. Customers are being instructed to return the affected products using the supplied return shipping label. Firm's contact information if questions or further assistance is needed: David Wang Sr. VP of Ops QA/RA D: 206-402-1146 8415 154th Avenue NE | Redmond, WA 98052 www.microsurgical.com [email protected]

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.

Our data sources and methodology