Medical devices, healthcare technology and the business of care
FDA RECALL RECORD · Z-0768-2025

Bodor P and C series laser cutting machines Recall

Bodor P and C series laser cutting machines

FDA recall Class II

Ongoing

FDA lists this Class II recall for Bodor P and C series laser cutting machines. Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-0768-2025
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
Dec 19, 2024
FDA report date
Jan 29, 2025
Quantity in commerce
269 units
Distribution
See key details
FDA cause
Radiation Control for Health and Safety Act

What is being recalled?

Bodor P and C series laser cutting machines

The retrieved code information does not contain explicit model/GTIN pairs that this publication can reliably map.

Search FDA identifier text

Search a model, catalog, lot or UDI value exactly as printed in FDA’s product description or code information.

This search checks only the FDA product description and code information displayed on this page. It does not decode a UDI, normalize GTIN lengths or establish a relationship between separately listed codes.

FDA code information

P series is 2421537-000 and C series is 2421612-000.

View the original FDA recall notice

Why was this product recalled?

Non-compliant laser products

What actions did Jinan Bodor Cnc Machine Co Ltd take?

Bodor Laser will write to inform all dealers and purchaser that the [P or C] series product(s) you purchased from Bodor may require an update. Specifically, Bodor will take the following steps: 1. For correction of defective products related to 21 CFR 1040.10(f)(1) Protective Housing, Bodor will perform inspections and installations of vision-based collision detection function to ensure that when an operator enters the protective enclosure, the equipment automatically detects their presence and stops operating. 2. For correction of defective products related to 21 CFR 1040.10(f)(2) Safety Interlocks, Bodor will perform inspections and installations of safety interlocks on the side doors to ensure that the equipment automatically stops when the side doors are The inspection, installation and/or repair, and testing may be conducted at your location. Bodor will remedy the defect or bring the product into compliance at no charge. Bodor will contact you to arrange a mutually agreeable time for the update operations to take place.

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.