CellMek SPS Sample Preparation System, REF: C44603, with software Recall
CellMek SPS Sample Preparation System, REF: C44603, with software
FDA recall Class II
Ongoing
FDA lists this Class II recall for CellMek SPS Sample Preparation System, REF: C44603, with software. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1235-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Dec 23, 2025
- FDA report date
- Feb 11, 2026
- Quantity in commerce
- 50
- Distribution
- See key details
- FDA cause
- Software change control
What is being recalled?
CellMek SPS Sample Preparation System, REF: C44603, with software
Affected model & UDI checker
Search the exact identifiers published for Z-1235-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| C44603 | CellMek SPS Sample Preparation System, REF: C44603, with software | Check source notice | Not specified |
| Not specified | CellMek SPS Sample Preparation System, REF: C44603, with software | Check source notice | 15099590750312 |
FDA code information
UDI-DI: 15099590750312. Software Version 2.3.90.0
Why was this product recalled?
Sample preparation system designed to automate staining, lysing, cell washing has a software error that causes samples to be dispensed close to or touching tube bottoms, which could dislodge fluid line, result in sample loss, spillage, make instrument inoperable and will lead to unintentional removal of 60-100 microliters from final sample, may lead to incorrect diagnosis or patient management.
What actions did BECKMAN COULTER, INC. take?
On 12/23/2025, recall notices were mailed and emailed to customers who were asked to do the following: 1) To mitigate the risk of contact between the dispense probe and the tube bottom, utilize CellMek SPS output tubes distributed by Beckman Coulter. 2) For absolute count assays, use the CellMek SPS on-board counting bead feature. Do not add counting beads to samples manually after preparation with CellMek SPS. 3) Share the content of this letter with your laboratory and/or medical director regarding the need to review previous patient test results. If you have forwarded any of the affected product listed above to another laboratory, please provide them a copy of this letter. 4) Firm recommends posting this letter on or near the affected instruments. 5) Complete and return the response form. Firm will perform an on-site service modification to update your instrument software to correct this issue. If you have any questions regarding this notice, please contact the firm's Customer Support Center: http://www.beckman.com, (800) 369-0333
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1235-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology