Bubble Sensor for 3/8" x 3/32" tubing; Recall
Bubble Sensor for 3/8" x 3/32" tubing; Model Number: 701055720;
FDA recall Class II
Ongoing
FDA lists this Class II recall for Bubble Sensor for 3/8" x 3/32" tubing;. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1300-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jan 9, 2026
- FDA report date
- Feb 11, 2026
- Quantity in commerce
- 3050 units
- Distribution
- See key details
- FDA cause
- Under Investigation by firm
What is being recalled?
Bubble Sensor for 3/8" x 3/32" tubing; Model Number: 701055720;
Affected model & UDI checker
Search the exact identifiers published for Z-1300-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 701055720 | Bubble Sensor for 3/8" x 3/32" tubing; | Check source notice | Not specified |
| Not specified | Bubble Sensor for 3/8" x 3/32" tubing; | Check source notice | 04037691816432 |
FDA code information
Model Number: 701055720; UDI-DI: 04037691816432; Serial Numbers: All units impacted;
Why was this product recalled?
Internal investigations have identified an issue with the durability of the connecting cable near the connection to the Venous Bubble Sensor. Excessive bending of the connecting cable can lead to full damage of the Venous Bubble Sensor or loose cable contact, which may trigger the errors Ven. bubble sensor defective or Ven. bubble sensor disconnected on the connected medical device. These errors can occur temporarily when the connecting cable is moved or permanently if the connection is fully compromised.
What actions did Maquet Cardiopulmonary Gmbh take?
On or around January 9, 2026, "URGENT MEDICAL DEVICE RECALL" letters were sent to customers. Customers were instructed to take the following actions: - Please examine your inventory immediately to determine if you have any affected product in your inventory and utilize the recommended mitigations listed above until replacement sensors are available. - Complete and return the enclosed response form Getinge by e-mailing a copy to [email protected]. - Contact Customer Service via email at [email protected] or 888-943-8872, ext 28849 / (888 9GETUSA), Monday through Friday, between the hours of 8:00 a.m. and 5:00 p.m. (Eastern Time Zone) to order a replacement sensor that will be shipped once available. Affected sensors will be returned to Getinge at time of replacement. - Please ensure this message is forwarded to any individuals that need notification within your organization or any organization where the affected devices have been transferred. If you have any questions, contact Customer Service via email at [email protected] or 888-943-8872, ext 28849 / (888 9GETUSA), Monday through Friday, between the hours of 8:00 a.m. and 5:00 p.m. (Eastern Time Zone).
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1300-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.