MicroScan Neg MIC 3J REF C54814 Recall
MicroScan Neg MIC 3J REF C54814
FDA recall Class II
Ongoing
FDA lists this Class II recall for MicroScan Neg MIC 3J REF C54814. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1772-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jun 25, 2025
- FDA report date
- Apr 15, 2026
- Quantity in commerce
- 688 boxes (20 panels per box)
- Distribution
- See key details
- FDA cause
- Process control
What is being recalled?
MicroScan Neg MIC 3J REF C54814
Affected model & UDI checker
Search the exact identifiers published for Z-1772-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| C54814 | MicroScan Neg MIC 3J REF C54814 | Check source notice | Not specified |
FDA code information
Catalog Number: C54814 UDI code: N/A Lot Number: 2025-08-23
Why was this product recalled?
Due to a manufacturing issue - missing a drug in well 4/4 but contain double the amount of antibiotics
What actions did BECKMAN COULTER, INC. take?
On 07/15/2024, firm sent via mail/email an "URGENT MEDICAL DEVICE RECALL" Letter to customer inform them that customers have reported multiple patient samples with skipped wells for Ceftolozane/Tazobactam (C/T) when tested with MicroScan Neg MIC 3J Lot 2025-08-23. The C/T 2/4 dilution well exhibited no growth while growth was observed in the C/T 4/4 well. Customers are instructed to: "Discontinue use of this lot and discard per your laboratory guidelines. "Consider reviewing the C/T antimicrobial susceptibility test results from this lot if Enterobacterales reported as resistant and P. aeruginosa reported as intermediate or if an increasing trend in resistance has been observed for C/T in your laboratory. "The laboratory should retain the inventory of other MicroScan Neg MIC 3J lots as they are not impacted by this issue. any questions regarding this notice, please contact us: "From our website: http://www.beckmancoulter.com "By phone: please contact: Customer call center TEL :0120-566-730
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1772-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.