Olympus EVIS EXERA III Duodenovideoscope. Recall
Olympus EVIS EXERA III Duodenovideoscope. Model Number: TJF-Q190V
FDA recall Class II
Ongoing
FDA lists this Class II recall for Olympus EVIS EXERA III Duodenovideoscope.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-1911-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- May 5, 2025
- FDA report date
- Jun 11, 2025
- Quantity in commerce
- 12,195 units
- Distribution
- See key details
- FDA cause
- Labeling design
What is being recalled?
Olympus EVIS EXERA III Duodenovideoscope. Model Number: TJF-Q190V
Affected model & UDI checker
Search the exact identifiers published for Z-1911-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| TJF-Q190V | Olympus EVIS EXERA III Duodenovideoscope. | Check source notice | Not specified |
| Not specified | Olympus EVIS EXERA III Duodenovideoscope. | Check source notice | 04953170405563 |
FDA code information
UDI-DI: 04953170405563. Model Number: TJF-Q190V. All serial numbers.
Why was this product recalled?
Recent post-market surveillance data suggests a possible association of higher microbial contamination levels from TJF duodenoscopes when manual cleaning was delayed beyond one hour and a presoak was performed, compared to those TJF duodenoscopes where manual cleaning began within one hour after patient procedure.
What actions did Olympus Corporation of the Americas take?
Olympus notified consignees on 05/05/2025 via "URGENT Medical Device Correction" letter. Consignees were instructed to carefully review the notification, ensure all reprocessing and endoscopy unit personnel are completely knowledgeable and thoroughly trained on the updated reprocessing instructions, replace any copies of the reprocessing manual with the updated version (RC8415_02), complete and return the response form to recall web portal: https://olympusamerica.com/recall, enter the recall number: "0471" and complete the form as instructed, and forward the notification to affected customers if the affected product has been further distributed. If you require additional information, please do not hesitate to contact me directly by phone at (647) 999-3203 or by e-mail [email protected].
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-1911-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology