Medical devices, healthcare technology and the business of care
FDA RECALL RECORD · Z-2033-2025

Jewel Precision Reusable Rigid Sterilization Container System. Recall

Jewel Precision Reusable Rigid Sterilization Container System. Model Number: JP-24-8.

FDA recall Class II

Ongoing

FDA lists this Class II recall for Jewel Precision Reusable Rigid Sterilization Container System.. Review the affected identifiers, reported reason and manufacturer instructions below.

Recall at a glance

Recall number
Z-2033-2025
Recall classification
Class II
Enforcement status
Ongoing
Initiation date
May 23, 2025
FDA report date
Jul 2, 2025
Quantity in commerce
1
Distribution
See key details
FDA cause
No Marketing Application

What is being recalled?

Jewel Precision Reusable Rigid Sterilization Container System. Model Number: JP-24-8.

Affected model & UDI checker

Search the exact identifiers published for Z-2033-2025.

The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.

Affected products

Model / catalog numberProductLot scope reportedUDI / GTIN
JP-24-8Jewel Precision Reusable Rigid Sterilization Container System.Check source noticeNot specified
Not specifiedJewel Precision Reusable Rigid Sterilization Container System.Check source notice00850043393139
FDA code information

Model No JP-24-8. GTIN: 00850043393139. Lot Number: 16899

View the original FDA recall notice

Why was this product recalled?

The 8-inch model of the Jewel Precision Reusable Rigid Sterilization Container System (i.e., model number: JP-24-8) was not cleared by the FDA. The letter to file justifying the change in size was insufficient.

What actions did Jewel Precision Sheet Metal & Machining Co, Inc. take?

Jewel Precision sent a "MEDICAL DEVICE RECALL" letter dated 5/23/2025 to the single consignee on 05/23/2025 via email. The consignee was instructed to; review all stock and inventory, return the product to Jewel Precision for destruction, complete the Acknowledgement and Receipt form on pages 3-4 of the letter indicating the actions taken and approval of completion, in the event that the product has been scrapped, please provide evidence of scrapping it and certification that the product has been destroyed by the customer. As per the customer's purchase order, the piece was to be used for testing purposes only. For products that have been shipped to your customers, identify and notify your customers of the recall, requesting return; obtain their acknowledgement and approval that the part has been shipped back. Action by company: discontinued the product. For questions email: [email protected] or call 973-857-5545 x19.

Read the manufacturer action recorded by FDA

Recall timeline

  1. Recall initiated by firm

  2. FDA notice posted

  3. FDA classification recorded

  4. FDA enforcement report date

Related FDA submissions

No submission number with an exact verified relationship is linked in the retrieved recall notice.

FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.

Source and update history

  1. FDA enforcement data

    First stored snapshot of this source.

  2. FDA device-recall notice

    First stored snapshot of this source.

The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.

Our data sources and methodology