SmartPath to dStream for XR and 3.0T Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129; Recall
SmartPath to dStream for XR and 3.0T Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129;
FDA recall Class II
Ongoing
FDA lists this Class II recall for SmartPath to dStream for XR and 3.0T Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129;. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2216-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jun 30, 2025
- FDA report date
- Aug 6, 2025
- Quantity in commerce
- 294 units
- Distribution
- See key details
- FDA cause
- Device Design
What is being recalled?
SmartPath to dStream for XR and 3.0T Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129;
The retrieved code information does not contain explicit model/GTIN pairs that this publication can reliably map.
Search FDA identifier text
Search a model, catalog, lot or UDI value exactly as printed in FDA’s product description or code information.
This search checks only the FDA product description and code information displayed on this page. It does not decode a UDI, normalize GTIN lengths or establish a relationship between separately listed codes.
FDA code information
Model Numbers (REF): (1) 781270, (2) 782113, (3) 782129; UDI-DI: (1) 00884838095083, (2) 00884838098909, (3) 00884838105805; Serial Numbers: (1) 17006, 17172, 17204, 17206, 17212, 17215, 17222, 17237, 17239, 17240, 17242, 17245, 17246, 17247, 17250, 17260, 17264, 17265, 17266, 17268, 17269, 17274, 17283, 17284, 17286, 17290, 17292, 17299, 17302, 17308, 17309, 17313, 17321, 17326, 17339, 17342, 17344, 17352, 17353, 17356, 17357, 17360, 17366, 17367, 17369, 17375, 17378, 17386, 17388, 17389, 17398, 17399, 17406, 17415, 17416, 17425, 17428, 17429, 17434, 17436, 17440, 17447, 17459, 17464, 17466, 17468, 17473, 17490, 17491, 17493, 17495, 17499, 17508, 17509, 17514, 17516, 17517, 17524, 17533, 17536, 17544, 17546, 17550, 17556, 17559, 17564, 17565, 17569, 17570, 17572, 17580, 17589, 17590, 17594, 17615, 23002, 23026, 23030, 23033, 23034, 23036, 24006, 24012, 24013, 24018, 24020, 24022, 24023, 24025, 24036, 24047, 24055, 24058, 24075, 24076, 24087, 24090, 24095, 24098, 24108, 24109, 24110, 24111, 24117, 24124, 24133, 24134, 24143, 24145, 34032, 34036, 34037, 34058, 34060, 34067, 34076, 34080, 34083, 34090, 34096, 34107, 34111, 34142, 34145, 34152, 34154, 34211, 34221, 34223, 34233, 34236, 34246, 34249, 34250, 34261, 34292, 35027, 35031, 35032, 35040, 35043, 35044, 35046, 35047, 35048, 35052, 35053, 35056, 35060, 35073, 35078, 35087, 38001, 38004, 38005, 38006, 38013, 38015, 38020, 38023, 38026, 38032, 38037, 38038, 38040, 38041, 38062, 38063, 38065, 38071, 38076, 38084, 38089, 38102, 38109, 38111, 38113, 38116, 38120, 38126, 38131, 38134, 38135, 38138, 38161, 38168, 38184, 38192, 38198, 38199, 38202, 38214, 38217, 38224, 38225, 38235, 38259, 38263, 38300, 38317, 38356, 38366, 74011, (2) 17238, 17252, 17258, 17271, 17307, 17346, 17372, 17376, 17439, 17449, 17455, 17461, 17470, 17504, 17521, 17560, 24021, 24039, 24052, 24077, 24093, 24146, 34056, 34059, 34072, 34110, 34117, 34127, 34128, 34129, 34130, 34131, 34143, 34153, 34172, 34202, 34212, 34262, 34304, 35041, 35045, 35059, 35071, 38010, 38011, 38042, 38049, 38066, 38070, 38075, 38082, 38094, 38105, 38106, 38117, 38142, 38166, 38197, 38219, 38222, 38230, 38234, 38281, 38290, 38310, 38311, 38354, 74036, 74040, (3) 34055, 38195;
Why was this product recalled?
The potential for component failures in the Gradient Coil of the affected MR systems may act as a heat source with a potential to produce smoke and/or fire.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Philips North America take?
On June 30, 2025, URGENT MEDICAL DEVICE CORRECTION letters were sent to customers. 4. Actions that should be taken by the customer / user in order to prevent risks for patients or users 4.1. When using any affected system identified according to the information in section 3, follow the instructions below. 4.2. Pay particular attention if a scan interruption occurs and a scan abort symbol is encountered, which may appear in the user interface (UI) with the symbols shown in Figure 4 below: Figure 4. Scan Abort Symbols 4.3. When scan aborts occur the symbol is shown and applicable messages are presented in the message box (see Figure 5 and Figure 6 examples) 4.3.1. Check the status of the error messages in the User Interface (UI) screen. Click to expand the message box in case previous messages are hidden, see orange box in Figure 5 and Figure 6 below. If possible, correct the issue that is relevant to the error shown and continue scanning, for example: RF door must be closed while performing scan. Scan aborted. Patient support is moved while scanning, scan stopped. Coil A (or B) failure, coil disconnected? . 4.3.2. If, after a scan abort, one of the following conditions occur five times in a row stop scanning immediately and contact Philips Service to describe the problem: If there is no error message in the message box If the error message meaning is not clear 4.3.3. If the error message Gradient amplifier Rack Fault is received two times in a row, or if the error message Gradient amplifier Rack Fault is preceded or followed by an aborted scan with no message, then stop scanning immediately and contact Philips Service to describe the problem. 4.3.4. If you encounter any of these conditions described in 4.3.2 or 4.3.3 do not attempt any additional/further scans, including without limitation do not attempt any phantom scanning until your system has been checked and released by a Philips Service representative. 4.4. If smoke and/or fire is detected
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2216-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology