DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457 Recall
DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457
FDA recall Class II
Ongoing
FDA lists this Class II recall for DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2267-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jun 25, 2025
- FDA report date
- Aug 13, 2025
- Quantity in commerce
- 1 system
- Distribution
- See key details
- FDA cause
- Device Design
What is being recalled?
DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457
Affected model & UDI checker
Search the exact identifiers published for Z-2267-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| Not specified | DxI 800 Access Immunoassay Analyzer W/Dual Gantry, Part Number A71457 | Check source notice | 15099590369231 |
FDA code information
UDI-DI: 15099590369231; Serial Numbers: 608109
Why was this product recalled?
Beckman Coulter has identified that the UniCel DxI 600/800 systems with linear slide PnP gantries running software versions 5.7 and up faced incorrect PnP X-motor current settings where the PnP X-motor current incorrectly resets to 1.5A (instead of the required 2.0A) because the software overwrites the factory setting during installs or upgrades. This anomaly causes increased PnP motion errors which could lead to delays in reporting patient sample results if unnoticed.
What actions did BECKMAN COULTER, INC. take?
An URGENT MEDICAL DEVICE RECALL notification dated 6/25/25 was sent to customers. ACTION: If your laboratory encounters any of the events described in this letter: " Perform a system initialization to resume normal operation. o If repeated initialization attempts fail, contact Customer Technical Support. " Repeat testing for any cancelled tests. " No action is required if your laboratory has not observed the events listed above ESOLUTION: "A Beckman Coulter representative will schedule the modification installation when it is available. Please share this information with your laboratory staff and retain this notification as part of your laboratory Quality System documentation. If you have forwarded any of the affected product listed above to another laboratory, please provide them a copy of this letter. So that we are assured you have received this important communication, please respond within 10 days in one of the following ways: " Electronically, if you received this communication via email. " Manually, complete and return the enclosed Response Form. If you have any questions regarding this notice, please contact our Customer Support: " From our website: http://www.beckmancoulter.com
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2267-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology