IDM-ARLITE-R. Electrical wheelchair component. Recall
IDM-ARLITE-R. Electrical wheelchair component.
FDA recall Class I
Ongoing
FDA lists this Class I recall for IDM-ARLITE-R. Electrical wheelchair component.. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2459-2025
- Recall classification
- Class I
- Enforcement status
- Ongoing
- Initiation date
- Jul 10, 2025
- FDA report date
- Sep 10, 2025
- Quantity in commerce
- 25 units
- Distribution
- See key details
- FDA cause
- Device Design
What is being recalled?
IDM-ARLITE-R. Electrical wheelchair component.
Affected model & UDI checker
Search the exact identifiers published for Z-2459-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| PRSPS00018 | IDM-ARLITE-R. Electrical wheelchair component. | Check source notice | Not specified |
| Not specified | IDM-ARLITE-R. Electrical wheelchair component. | Check source notice | 05407008320102 |
FDA code information
Model No. PRSPS00018. UDI-DI: 05407008320102; Serial No. 1000 to 2647.
Why was this product recalled?
Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did mo-Vis BVBA take?
An URGENT: MEDICAL DEVICE RECALL R-NET JOYSTICKS notification dated 07/10/2025 was sent to consignees instructing them to upgrade affected devices according to the provided Annex 2 or by emailing [email protected] to coordinate return. The software upgrade of affected devices should be conducted during the next scheduled annual maintenance of the joystick. These actions should be verified. Questions can be directed via email to [email protected] or by phone at +32 9 335 28 60.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2459-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology