Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09 Recall
Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09
FDA recall Class II
Ongoing
FDA lists this Class II recall for Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2558-2025
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jul 8, 2025
- FDA report date
- Sep 24, 2025
- Quantity in commerce
- 25,260
- Distribution
- See key details
- FDA cause
- Labeling design
What is being recalled?
Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09
Affected model & UDI checker
Search the exact identifiers published for Z-2558-2025.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| Not specified | Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09 | Check source notice | 08714729985044 |
| Not specified | Vercise Deep Brain Stimulation Systems Surgical Implant Manual, Document Number: 92328632-09 | Check source notice | 08714729985051 |
FDA code information
UDI-DI: 08714729985044, 08714729985051. Document Number/Revision: 92328632-09, Rev A
Why was this product recalled?
Wire break(s) have occurred in rechargeable deep brain stimulation implantable pulse generators, implanted in the submuscular pectoral location. Wire breaks prevent successful stimulation, thus requiring device removal/replacement and users may experience high monopolar impedances, undesired sensation, loss of therapy, return of symptoms and/or Bluetooth connectivity challenges.
What actions did Boston Scientific Neuromodulation Corporation take?
On 7/8/2025, correction notices were mailed in the U.S. and mailed, emailed, or hand delivered outside the U.S. Healthcare Professionals were asked to do the following: 1) Review the Surgical Implant Manual updates. 2) If you are a facility that has sent products to another hospital or a facility within your network, ensure this notification is forwarded to them. 3) A patient letter is enclosed with this communication, which can be shared with your patient and/or included within the patient's medical record. 4) Monitor per relevant IFU recommendations for any clinical observations of high monopolar impedances, undesired sensation, sudden loss of therapy, return of pre-implant symptoms and/or Bluetooth connectivity challenges, as these may be signals of potential feedthrough wire break(s) (component damage). 5) If you are a distributor, this notification must be forwarded to your customers to ensure this notification is carried out to the end-user level. 6) To provide awareness of this information, share this letter with any other clinicians in your hospital who use the system. 7) Maintain a copy of this letter in your facility's records. 8) Complete and return the acknowledgement form via email to [email protected] report all device-related incidents or quality concerns experienced with the use of these devices to the firm at [email protected]
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2558-2025
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 22, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 22, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology