GC Agar Base (150mm) 10/PK R04030; GC Agar Base (100mm) 10/PK R01460 Recall
GC Agar Base (150mm) 10/PK R04030; GC Agar Base (100mm) 10/PK R01460
FDA recall Class II
Ongoing
FDA lists this Class II recall for GC Agar Base (150mm) 10/PK R04030; GC Agar Base (100mm) 10/PK R01460. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2623-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- Jun 3, 2026
- FDA report date
- Jul 8, 2026
- Quantity in commerce
- 1573
- Distribution
- See key details
- FDA cause
- Under Investigation by firm
What is being recalled?
GC Agar Base (150mm) 10/PK R04030; GC Agar Base (100mm) 10/PK R01460
Affected model & UDI checker
Search the exact identifiers published for Z-2623-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| Not specified | GC Agar Base (150mm) 10/PK R04030; GC Agar Base (100mm) 10/PK R01460 | Check source notice | 848838001796 |
| Not specified | GC Agar Base (150mm) 10/PK R04030; GC Agar Base (100mm) 10/PK R01460 | Check source notice | 848838004469 |
FDA code information
R01460 - GC Agar Base (100mm) 10/PK UDI-DI 848838001796 Lots 338950 356898 359912 365679 371863 376799 382136 384712 393488 396333 402458; R04030 - GC Agar Base (150mm) 10/PK UDI-DI 848838004469 Lots 336864 345992 348754 359925 367829 374235 376786 381488 385224 391312 393478
Why was this product recalled?
Reduced or no recovery of some strains of Neisseria gonorrhoeae.
What actions did Remel, Inc take?
On June 3, 2026, the firm began notifying customers via letters titled Urgent Medical Device Recall. Customers were instructed to destroy any remaining inventory of affected lots and inform the recalling firm of the amount destroyed to receive a replacement or credit. In addition, customers should notify necessary personnel. Users should review previously reported results generated using the affected lots and assess whether retesting is appropriate based on laboratory procedures.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2623-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 20, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 20, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology