Medtronic Harmony Delivery Catheter System Recall
Medtronic Harmony Delivery Catheter System
FDA recall Class I
Ongoing
FDA lists this Class I recall for Medtronic Harmony Delivery Catheter System. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2624-2026
- Recall classification
- Class I
- Enforcement status
- Ongoing
- Initiation date
- May 22, 2026
- FDA report date
- Jul 8, 2026
- Quantity in commerce
- 1881 units
- Distribution
- See key details
- FDA cause
- Process control
What is being recalled?
Medtronic Harmony Delivery Catheter System
Affected model & UDI checker
Search the exact identifiers published for Z-2624-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| Not specified | Medtronic Harmony Delivery Catheter System | Check source notice | 00763000341367 |
| Not specified | Medtronic Harmony Delivery Catheter System | Check source notice | 00763000544027 |
| Not specified | Medtronic Harmony Delivery Catheter System | Check source notice | 00763000520151 |
| Not specified | Medtronic Harmony Delivery Catheter System | Check source notice | 00763000582951 |
| Not specified | Medtronic Harmony Delivery Catheter System | Check source notice | 00763000918712 |
FDA code information
GTIN 00763000341367, Lot Numbers: 0012508285, 0012517045, 0012526102, 0012526103, 0012614786, 0012614787, 0012623740, 0012623741, 0012642959, 0012659419, 0012663878, 0012663879, 0012690218, 0012699635, 0012702022, 0012710787, 0012728367, 0012728369, 0012777713, 0012804152, 0012804579, 0012824770, 0012824771, 0012874526, 0012896853, 0012896884, 0012910323, 0012965210, 0012965211, 0012976400, 0012986693, 0013063766, 0013063767, 0013105039, 0013105040, 0013133457, 0013181623, 0013181624, 0013236643, 0013272796, 0013272798. GTIN 00763000544027, Lot Numbers: 0012508285, 0012526103, 0012614786, 0012614787, 0012623740, 0012623741, 0012642959, 0012659419, 0012663879, 0012702022, 0012710787, 0012728367, 0012728369, 0012777713, 0012804152, 0012804579, 0012824771, 0012874526, 0012896853, 0012896884, 0012910323, 0012965211, 0012976400, 0012986693, 0013063767, 0013105039, 0013105040, 0013133457, 0013181623, 0013181624. GTIN 00763000520151, Lot Numbers: 0012575897, 0012642965, 0012728368, 0013272799. GTIN 00763000582951, Lot Numbers: 0012590535, 0012606411, 0012606413, 0012642964, 0012659418, 0012678282, 0012690219, 0012699637, 0012804151, 0012804580, 0012874527, 0012888682, 0012896885, 0012965221, 0012986699, 0013063764, 0013063765, 0013105037, 0013227504. GTIN 00763000918712, Lot Numbers: 0012635392, 0012676200, 0012690207, 0012874528, 0012874529, 0013015539, 0013105038.
Why was this product recalled?
Devices containing inner shaft assemblies from specific manufacturing lots may have an increased potential for distal tip detachment from the delivery system under certain procedural or anatomical conditions due to a manufacturing issue.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Medtronic Heart Valves Division take?
Medtronic issued an URGENT MEDICAL DEVICE RECALL notice to its consignees on 5/28/2026 via mail or email. The notice explained the issue, potential risk, and requested the following: " - Review your inventory for affected lot numbers listed. - If unused inventory from the listed lot numbers is located, immediately quarantine and return the affected units to Medtronic by contacting Customer Service at 1-800-854-3570, Option 1 then Option 4, and referencing this communication to initiate return and exchange or credit of the affected units. Your Medtronic sales representative can assist in the return of the affected units as necessary. - Please share this notification with implanters and teams within your organization. If product listed above has been forwarded from your facility to another facility, please notify the other facility of this Medtronic Urgent Medical Device Recall. - Complete the enclosed Customer Confirmation Form and email to [email protected]. This form must be returned even if you do not have the affected units in your possession. - Please maintain a copy of this communication in your records."
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2624-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology