5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; Recall
5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; Model Number: 03-5110-6. 2. 5008X HD/HDF Standard Blood Tubing Set; Model Number: 03-5300-3. 3. 5008X HD/HDF With CLiC Blood Tubing Set; Model Number: 03-5300-3C. 4. 5008X HD/HDF With Twister Blood Tubing Set; Model Number: 03-5350-8.
FDA recall Class II
Ongoing
FDA lists this Class II recall for 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set;. Review the affected identifiers, reported reason and manufacturer instructions below.
Recall at a glance
- Recall number
- Z-2702-2026
- Recall classification
- Class II
- Enforcement status
- Ongoing
- Initiation date
- May 11, 2026
- FDA report date
- Jul 15, 2026
- Quantity in commerce
- 113,544 units (4,731 cases)
- Distribution
- See key details
- FDA cause
- Process control
What is being recalled?
5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; Model Number: 03-5110-6. 2. 5008X HD/HDF Standard Blood Tubing Set; Model Number: 03-5300-3. 3. 5008X HD/HDF With CLiC Blood Tubing Set; Model Number: 03-5300-3C. 4. 5008X HD/HDF With Twister Blood Tubing Set; Model Number: 03-5350-8.
Affected model & UDI checker
Search the exact identifiers published for Z-2702-2026.
The lookup covers structured identifiers listed on this page. A full UDI may also contain lot or serial information; a GTIN match alone does not check those conditions.
Affected products
| Model / catalog number | Product | Lot scope reported | UDI / GTIN |
|---|---|---|---|
| 03-5110-6 | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | Not specified |
| 03-5300-3 | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | Not specified |
| 03-5300-3C | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | Not specified |
| 03-5350-8 | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | Not specified |
| Not specified | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | 00840861102556 |
| Not specified | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | 00840861102518 |
| Not specified | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | 00840861102532 |
| Not specified | 5008X Blood Tubing Set, 24 units per case. Includes the below model numbers and descriptions. 1. 5008X HD Pre-Flush Standard Blood Tubing Set; | Check source notice | 00840861102525 |
FDA code information
Sets manufactured after February 26, 2026 1. Model Number: 03-5110-6; UDI-DI: 00840861102556; Lot Number: 26BR01177. 2. Model Number: 03-5300-3; UDI-DI: 00840861102518; Lot Numbers: 26BR01184, 26BR01202, 26CR01025, 26CR01039, 26CR01803, 26BR01185, 26BR01214, 26CR01026, 26CR01040, 26CR01804, 26BR01188, 26BR01215, 26CR01027, 26CR01041, 26DR01134, 26BR01189, 26BR01805, 26CR01029, 26CR01043, 26BR01201, 26CR01003, 26CR01034, 26CR01800. 3. Model Number: 03-5300-3C; UDI-DI: 00840861102532; Lot Numbers: 26CR01018, 26CR01020, 26DR01129, 26DR01150, 26CR01019, 26CR01021, 26DR01130, 26DR01151. 4. Model Number: 03-5350-8; UDI-DI: 00840861102525; Lot Numbers: 26CR01017, 26DR01077, 26DR01079, 26DR01080.
Why was this product recalled?
Potential for Online Port Errors due to connection issues when connecting the SafeLine of the 5008X CAREset to the substitution fluid port of the 5008X CAREsystem.
These are potential consequences described in the source. The recall reason does not establish how many injuries or incidents occurred.
What actions did Fresenius Medical Care Holdings, Inc. take?
Fresenius Medical Care notified consignees on about 05/11/2026 via "IMPORTANT MEDICAL DEVICE INFORMATION" letter. Consignees were informed of the issue of potential Online Port Errors and additional information to support proper connection of the SafeLine of the 5008X CAREset to the substitution fluid port of the 5008X CAREsystem. When pushing the substitution fluid connector (SafeLineTM) into the substitution fluid port, firmly insert the substitution fluid connector until you feel resistance. Check that there is no visible gap between the ring of the connector and the module. In the case of a visible gap between the ring of the connector and the module surface, apply pressure and push the connector to close the gap before automatic closure of the substitution fluid port door. Fresenius Medical Care is assessing improvements to restore the usual handling and user experience. FMCRTG is not requesting return of any product. ***Update*** On 06/292026, the firm sent a follow-up letter to consignees via First Class Mail. The updated letter states the firm has initiated shipments of limited quantities of new unaffected product. Customers are instructed to preferentially use unaffected lots of the tubing sets. If the customer needs to administer treatment and there are no alternatives available, they may use the affected lots of tubing sets to provide therapy, but only if they follow the specific instructions for using these affected sets. Unaffected lots of product do not require additional effort to seat the connector into the port. ***Update*** On 08/10/2026, the firm sent a follow up letter to consignees notifying them that product stock is available to replace affected products and the notification included specific lot numbers affected.
Read the manufacturer action recorded by FDARecall timeline
Recall initiated by firm
FDA notice posted
FDA classification recorded
FDA enforcement report date
Related FDA submissions
No submission number with an exact verified relationship is linked in the retrieved recall notice.
FDA’s notice explicitly links the submission numbers shown here. Read each filing for its own recorded device and scope.
Source and update history
- FDA recall notice Z-2702-2026
- openFDA enforcement record · Source release Nov 11, 2026 · Retrieved Nov 21, 2026
- openFDA device recall record · Source release Nov 19, 2026 · Retrieved Nov 21, 2026
- FDA enforcement data
First stored snapshot of this source.
- FDA device-recall notice
First stored snapshot of this source.
The history starts with the versions held by MedtechLedger. Earlier source changes are not reconstructed. Official dates and recorded status come from FDA; page summaries describe the source information.
Our data sources and methodology