FDA 510(k) records linked by MedtechLedger list Karl Storz SE & CO. KG as applicant on six premarket notifications, all carrying the SESE decision code, which the records describe as Substantially Equivalent. The filings span gynecologic hysteroscopy and endoscopic coagulation-cutting devices, ear, nose and throat irrigation sheaths, and a neurology endoscope. Each record names a distinct device or device family, and the accompanying FDA decision letters give the clearance dates used below. The collection is a snapshot of the linked filings as of November 20, 2026, not a statement of total company portfolio, sales or safety performance. [1][2][3][4][5]

Gynecologic and hysteroscopic filings

K254252 covers the UNIDRIVE SIII System together with a HOPKINS Telescope 0º (26205AMA), an Operating Sheath (26205CD), an Obturator (26205OC) and several Shaver Blades (26205SA, 26205SB, 091133-01/-10 and 091134-01/-10). The FDA record places it under product code HIH, regulation 884.1690 for hysteroscopes and accessories, with a decision date of September 25, 2026. The FDA decision letter for the same submission is dated September 25, 2026. [2][6]

K261102 covers the UNIDRIVE Select System under the same product code HIH and regulation, with a decision date of September 18, 2026; its FDA letter carries the same date. K254303 covers KARL STORZ SUPRALOOP under product code KNF, regulation 884.4160 for unipolar endoscopic coagulator-cutters and accessories, decided September 24, 2026. The SUPRALOOP 510(k) summary describes bench verification testing of electrode attaching and detaching force, system interlocking, bending force, high-frequency tissue and durability, compression and tensile strength, plus biocompatibility evaluation to ISO 10993, with results reported as meeting predefined acceptance criteria. [3][4][7][8]

ENT and neurology devices

K254299 covers CLEARVISION Irrigation Sheaths in 0° (7241AS), 30° (7241BS) and 45° (7241FS) configurations, filed under product code EOB, regulation 874.4760 for nasopharyngoscopes, with a decision date of September 15, 2026. The FDA letter for that submission notes that the device follows FDA-recognized consensus standards and references ISO 17665-1 on moist heat sterilization. [5][9]

K260581 covers the KARL STORZ Flexible Video Neuro-Endoscope under product code GWG, regulation 882.1480 for neurological endoscopes, with a decision date of October 14, 2026 and a receipt date of February 20, 2026. The record lists the advisory committee as Neurology and the clearance type as Traditional. [1]

Applicant identity and filing scope

The applicant name on these records is Karl Storz SE & CO. KG, with a Tuttlingen, Germany address in the FDA entries. That address is a filing address in the records and is not treated here as a verified headquarters. The K261102 letter identifies KARL STORZ Endoscopy-America, Inc. at 2151 E. Grand Avenue, El Segundo, California, as submitter, and the K254303 letter addresses correspondence to a regulatory affairs specialist at that El Segundo address. [1][2][3][4][7][8]

The linked collection contains six 510(k) records, all with the SESE decision code. The smaller record sample of five entries also shows five SESE decisions. These counts describe the linked filings only and are not measures of total company clearances, commercial availability or device performance. No parent, brand or ownership relationship beyond the applicant and submitter names in the records is verified here. [1][2][3][4][5]

What the records do and do not establish

The FDA letters state that the agency reviewed each section 510(k) premarket notification and cleared the referenced device for marketing, and they list compliance obligations such as registration and listing under 21 CFR Part 807 and labeling under 21 CFR Part 801. The K260884 letter for the UNIDRIVE Select System also references cybersecurity guidance for medical devices. These documents establish clearance and stated testing scope; they do not establish clinical outcomes, pricing, customer adoption or post-market safety results. [8][9][10]